Test Code CLLDF Chronic Lymphocytic Leukemia, Diagnostic FISH, Varies
Ordering Guidance
This test is intended for instances when the entire chronic lymphocytic leukemia (CLL) fluorescence in situ hybridization (FISH) panel is needed.
If a paraffin-embedded tissue sample is received, this test will be canceled and automatically reordered by the laboratory as SLL / Small Lymphocytic Lymphoma, FISH, Tissue.
Shipping Instructions
Advise Express Mail or equivalent if not on courier service.
Necessary Information
A reason for testing and a flow cytometry and/or a bone marrow pathology report are requested with each specimen. The laboratory will not reject testing if this information is not provided; however, appropriate testing and/or interpretation may be compromised or delayed in some instances. If not provided, an appropriate indication for testing may be entered by Mayo Clinic Laboratories.
Specimen Required
Submit only 1 of the following specimens:
Preferred:
Specimen Type: Blood
Container/Tube:
Preferred: Yellow top (ACD)
Acceptable: Green top (heparin) or lavender top (EDTA)
Specimen Volume: 6 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood in original tube. Do not aliquot.
Acceptable:
Specimen Type: Bone marrow
Container/Tube:
Preferred: Yellow top (ACD)
Acceptable: Green top (heparin) or lavender top (EDTA)
Specimen Volume: 2 to 3 mL
Collection Instructions:
1. It is preferable to send the first aspirate from the bone marrow collection.
2. Invert several times to mix bone marrow.
3. Send bone marrow in original tube. Do not aliquot.
Secondary ID
610713Useful For
Detecting recurrent common chromosome abnormalities in patients with chronic lymphocytic leukemia (CLL)
Distinguishing patients with 11;14 translocations who have the leukemic phase of mantle cell lymphoma from patients who have CLL
Detecting patients with atypical CLL with translocations between IGH and BCL3
Evaluating specimens in which chromosome studies are unsuccessful
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
CLLDB | Probe, Each Additional (CLLDF) | No, (Bill Only) | No |
Testing Algorithm
This test includes a charge for the probe application, analysis, and professional interpretation of results for 6 probe sets (12 individual fluorescence in situ hybridization [FISH] probes). Additional charges will be incurred for all reflex or additional probe sets performed.
This test is performed as panel testing only and will be performed using the following analysis algorithm. Modifications of the FISH probes or chronic lymphocytic leukemia (CLL) algorithm are not allowed for this test.
The panel includes testing for the following abnormalities using the probes listed:
6q-, D6Z1/MYB
11q-, D11Z1/ATM
+12, D12Z3/MDM2
13q-, D13S319/LAMP1
17p-, TP53/D17Z1
t(11;14), CCND1/IGH
Appropriate ancillary probes may be performed at consultant discretion to render comprehensive assessment. Any additional probes will have the results included within the final report and will be performed at an additional charge.
In the absence of CCND1::IGH fusion, when an extra IGH signal is identified, additional testing using the IGH/BCL3 probe set will be considered at the laboratory's discretion to identify a potential IGH::BCL3 fusion [t(14;19)(q32;q13)]. Laboratory discretion may be influenced by available karyotype results and previous CLL FISH testing.
Method Name
Reporting Name
CLL, Diagnostic FISHSpecimen Type
VariesSpecimen Minimum Volume
Blood: 2 mL; Bone marrow: 1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Ambient (preferred) | ||
Refrigerated |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Chronic lymphocytic leukemia (CLL) is one of the most common leukemias in adults. The most frequently seen cytogenetic abnormalities in CLL involve chromosomes 6, 11, 12, 13 and 17. These are detected and quantified using the CLL fluorescence in situ hybridization (FISH) panel.
Use of CpG-oligonucleotide mitogen will identify an abnormal CLL karyotype in at least 80% of cases. This mitogen is added to cultures when chromosome analysis is ordered and the reason for testing is B-cell lymphoproliferative disorders (CHRBM / Chromosome Analysis, Hematologic Disorders, Bone Marrow and CHRHB / Chromosome Analysis, Hematologic Disorders, Blood).
This FISH test detects an abnormal clone in approximately 70% of patients with indolent disease and in greater than 80% of patients who require treatment. At least 5% of patients referred for CLL FISH testing have translocations involving the IGH locus. Fusion of IGH with CCND1 is associated with t(11;14)(q13;q32), and fusion of IGH with BCL3 is associated with t(14;19)(q32;q13.3). Patients with t(11;14) usually have the leukemic phase of mantle cell lymphoma. Patients with t(14;19) may have an atypical form of B-CLL or the leukemic phase of a lymphoma.
The prognostic associations for chromosome abnormalities detected by this FISH assay are, from best to worst: 13q-, normal, +12, 6q-, 11q- and 17p-.
Reference Values
An interpretive report will be provided.
Interpretation
A neoplastic clone is detected when the percent of cells with an abnormality exceeds the normal reference range for any given probe set.
The absence of an abnormal clone does not rule out the presence of a CLL clone or another neoplastic disorder.
Cautions
This test is not approved by the US Food and Drug Administration, and it is best used as an adjunct to existing clinical and pathologic information.
Supportive Data
Each probe was independently tested and verified on unstimulated peripheral blood and bone marrow specimens. Normal cutoffs were calculated based on the results of at least 25 normal specimens. In addition, each probe set was evaluated in a blinded fashion to confirm the probe set detected the abnormality it was designed to detect.
Clinical Reference
1. Dewald GW, Brockman SR, Paternoster SF, et al: Chromosome anomalies detected by interphase FISH: correlation with significant biological features of B-cell chronic lymphocytic leukemia. Br J Haematol. 2003;121:287-295
2. Dohner H, Stilgenbauer S, Benner A, et al. Genomic aberrations and survival in chronic lymphocytic leukemia. N Engl J Med. 2000;343(26):1910-1916
3. Van Dyke DL, Shanafelt TD, Call TG, et al. A comprehensive evaluation of the prognostic significance of 13q deletions in patients with B-chronic lymphocytic leukaemia. Br J Haematol. 2010;148:544-550
4. Shanafelt TD: Predicting clinical outcome in CLL: how and why. Hematology Am Soc Hematol Educ Program. 2009;421-429
5. Van Dyke DL, Werner L, Rassenti LZ, et al. The Dohner fluorescence in situ hybridization prognostic classification of chronic lymphocytic leukaemia (CLL): the CLL Research Consortium experience. Br J Haematol. 2016;173(1):105-113
6. Fang H, Reichard KK, Rabe KG, et al. IGH translocations in chronic lymphocytic leukemia: Clinicopathologic features and clinical outcomes. Am J Hematol. 2019;94(3):338-345
7. Huh YO, Schweighofer CD, Ketterling RP, et al. Chronic lymphocytic leukemia with t(14;19)(q32;q13) is characterized by atypical morphologic and immunophenotypic features and distinctive genetic features. Am J Clin Pathol. 2011;135(5):686-696
Method Description
This test is performed using commercially available and laboratory-developed probes. Deletion of chromosomes 6q, 11q, 13q and 17p, and trisomy of chromosome 12 are detected using enumeration strategy probes. A dual-color, dual-fusion fluorescence in situ hybridization (D-FISH) strategy probe set is used to detect CCND1::IGH rearrangements and for reflex testing to identify IGH::BCL3 rearrangements. For enumeration strategy probe sets, 100 interphase nuclei are scored; 200 interphase nuclei are scored when D-FISH probes are used. All results are expressed as the percent abnormal nuclei.(Unpublished Mayo method)
Day(s) Performed
Monday through Friday
Report Available
7 to 10 daysSpecimen Retention Time
4 weeksPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
88271x12, 88275x6, 88291-FISH Probe, Analysis, Interpretation; 6 probe sets
88271x2, 88275-FISH Probe, Analysis; each additional probe set (if appropriate)
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CLLDF | CLL, Diagnostic FISH | 101788-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
610714 | Result Summary | 50397-9 |
610715 | Interpretation | 69965-2 |
610716 | Result Table | 93356-4 |
610717 | Result | 62356-1 |
GC088 | Reason for Referral | 42349-1 |
GC089 | Specimen | 31208-2 |
610718 | Source | 31208-2 |
610719 | Method | 85069-3 |
610720 | Additional Information | 48767-8 |
610721 | Disclaimer | 62364-5 |
610722 | Released by | 18771-6 |
Forms
If not ordering electronically, complete, print, and send a Hematopathology/Cytogenetics Test Request (T726) with the specimen.