Sign in →

Test Code F100B S-100B Protein, Serum

Reporting Name

S-100B Protein, Serum

Performing Laboratory

ARUP Laboratories

Specimen Type

Serum


Specimen Required


Collection Container/Tube: Red top or serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 2 mL serum

Collection Instructions:

1. Allow specimen to clot completely at ambient temperature.

2. Within 2 hours of collection, centrifuge and aliquot 2 mL of serum into a plastic vial.

3. Send refrigerate.


Specimen Minimum Volume

Serum: 0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 7 days
  Frozen  90 days
  Ambient  24 hours

Reference Values

0 days to 5 months: ≤510 ng/mL

5 months to 10 months: ≤350 ng/mL

10 months to 25 months: ≤230 ng/L

25 months to 3 years: ≤170 ng/L

3 years to 19 years: ≤160 ng/L

19 years and older: 0-96 ng/L

Day(s) Performed

Tuesday

Test Classification

This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.

CPT Code Information

86316

LOINC Code Information

Test ID Test Order Name Order LOINC Value
F100B S-100B Protein, Serum 47275-3

 

Result ID Test Result Name Result LOINC Value
Z2708 S-100B Protein, S 47275-3

Report Available

1 to 18 days

Reject Due To

 Thawing: Cold OK; Warm reject
  All specimens will be evaluated by the processing and performing laboratories for test suitability.

Method Name

Quantitative Enzyme-Linked Immunosorbent Assay

Cautions

Results obtained with different assay methods or kits cannot be used interchangeably.

Method Description

This assay is performed using the CanAg S100 Enzyme Immunoassay.

Clinical Information

Refer to https://ltd.aruplab.com/