Sign in →

Test Code LAB4282 HEPATITIS B ONCOLOGY PROFILE 

Important Note

Reactive Hepatitis B Core, Total results for this panel will reflex to Hepatitis B Virus (HBV) DNA Detection and Quantification by Real-Time PCR, Serum (HBVQN, LAB5190) which will be performed at Mayo Clinic Lab.

Additional Codes

This panel includes the following tests:

LAB4122 Hepatitis B Surface Antigen

LAB4120 Hepatitis B Core Antibody, Total

Specimen Type

Preferred Specimen: Serum (SST, Gold, Corvac, Tiger, Red Top Tube)

Alternative Specimen:   Lithium Heprin Plasma (Light Green/Dark Green Top Tube)

Caution: The confirmatory test (HBVQN) for a reactive Hepatitis B Core, Total result requires a serum SST tube. 

Specimen Volume

2.0 mL

Minimum Volume

1.0 mL

Turnaround Time

STAT: 1 hour

Timed:4 hours

Routine: 4 hours

Test Schedule

Daily

Sample Stability

Room Temperature: 24 hours

Refrigerated: 6 days

Frozen: N/A

Method

Chemiluminescent microparticle immunoassay (CMIA)

Reference Ranges

Non-Reactive

CPT Codes

86704, 87340

Test Components

Hepatitis B Surface Antigen

Hepatitis B Core Antibody, Total