Test Code LAB4685 TROPONIN I,HS MI RULE OUT ALGORITHM
Specimen Type
Lithium Heparin Plasma (Mint/Light Green Top)
Specimen Volume
1 mL
Minimum Volume
0.5 mL
Turnaround Time
STAT: 1 hour
Routine: 1 hour
Test Schedule
Daily
Sample Stability
Room temperature: 8 hours
Method
Electrochemiluminesence
Reference Ranges
Troponin-I ng/L
Normal Range:
Normal Female: < 14 ng/L
Normal Male: < 35 ng/L
Critical Results
Troponin > 64 ng/L
Reporting Limit
2.7 - 108,000 ng/L
Test Components
Troponin-I, ng/L
CPT Codes
84484
Rejection Criteria
Hemolysis > 1000 mg/dL
Icterus > 30 mg/dL
Lipemia > 3000 mg/dL