Sign in →

Test Code LAB6927 TEG BASIC HEPARIN NEUTRALIZATION

Important Note

Use only BD Vacutainer blue top tubes for this test. Do not use Greiner blue top tubes.

Specimen Requirements

BD Vacutainer Blue top tube (buffered 3.2% liquid sodium citrate) filled to the indicator with whole blood

 

Venipuncture: Use a 21 gauge needle or larger. Drawing a discard tube with no additive or discard syringe of 3-5 mL prior to collecting blood is strongly recommended. Suitable discard tubes include no additive tubes or a second blue top marked "discard." After collection, gently invert the tube 5 times to mix.

Line Draw: When drawing from a line, be sure to use plastic syringes that are not heparinized. Using two syringes, discard 3x's the dead space (typically 10 mL). Using a safe transfer device (or a standard needle no smaller than 21 gauge), allow the blood collection tube to fill completely by vacuum. After collection, gently invert the tube 5 times to mix.

Specimen Volume

1.8mL BD Vacutainer Blue top (3.2% Sodium Citrate)

Turnaround Time

STAT: 2 hours
Routine: 2 hours

Test Schedule

Daily

Sample Stability

Blue top whole blood: 2 hours at 20-25oC

Specimen Processing

Liquid blue top tube filled to capacity. Must be performed within 2 hours of collection.

Method

Viscoelastic

Reference Ranges

Test Range
Citrated Kaolin Reaction Time 4.6 - 9.1 min
Citrated Kaolin Max Amplitude 52.0 - 69.0 mm
Citrated Kaolin w/Heparinase Reaction Time 4.3 - 8.3 min
Citrated Kaolin w/Heparinase Lysis 0.0 - 3.2%
Citrated RapidTEG w/Heparinase Max Amplitude 53.0 - 69.0 mm
Citrated Functional Fibrinogen w/Heparinase Max Amplitude 15.0 - 34.0 mm

 

Synonyms

HN, TEG, TEG 6, TEG 6S, Citrated Kaolin, Citrated Kaolin w/Heparinase, Citrated RapidTeg, Citrated Functional Fibrinogen, Hemostasis

Test Components

Citrated Kaolin Reaction Time

Citrated Kaolin Max Amplitude

Citrated Kaolin w/Heparinase Reaction Time

Citrated Kaolin w/Heparinase Lysis

Citrated RapidTEG w/Heparinase Max Amplitude

Citrated Functional Fibrinogen w/Heparinase Max Amplitude

Rejection Criteria

Clotted specimens, improperly filled liquid blue top tube, specimens drawn with a needle smaller than 21 gauge, specimens more than 2 hours old, refrigerated or frozen specimens

CPT Codes

Test Code
Citrated Kaolin Reaction Time 85347
Citrated Kaolin Max Amplitude 85576
Citrated Kaolin w/Heparinase Reaction Time 85347-59
Citrated Kaolin w/Heparinase Lysis 85390
Citrated RapidTEG w/Heparinase Max Amplitude 85576-59
Citrated Functional Fibrinogen w/Heparinase Max Amplitude 85384